Compliant Standards: IEC 61287-1 (Edition 2.0), IEC-60571 (Edition 2.1), IEC- 60310 (Edition 3.0), IEC 61373 (Edition 2.0), and other relevant IEC and Indian (BIS) standards.
Technical Features
State of the art DSP based system.
Stabilized and balanced output (6 – 12 V DC adjustable).
Wide DC input variation (500 – 990 V DC).
Maintenance free, being fully static.
Low noise level.
Underslung structure with IP65 protection class.
Online monitoring.
Event and Data logging facility.
Output galvanically isolated from input.
Natural cooled.
Applications
Converts third rail DC input voltage with wide variation to stabilized 6 - 12 V DC (capacity 417 Amp) for the safe and reliable operation of DC motor braking, for metro vehicles.
Technical Specifications
(A) Input
Factors
Values
Nominal Voltage
750 V DC
Range 500 – 990 V DC
including ripple 4.5%
(B) Output
Factors
Values
Output power
5 kW (nominal operation)
Over load
6 kW for 5 seconds
Voltage
6 - 12 V DC
Output voltage ripple
< 5%
Output DC current ripple
< 3%
Efficiency
≥92%
(C) General
Factors
Values
Operating ambient temperature
5°C to 55°C
Cooling
Natural
Display & Communication part
Vacuum fluorescent display (VFD and RS232, CAN part for data retrieval)