Underslung 50 kVA (25 kVA AC and 25 kW DC) IGBT based converter for Metros.
Compliant Stadards: IEC 61287-1 (Edition 2.0), IEC 60571 (Edition 2.1), IEC 60310 (Edition 3.0), IEC 61373 (Edition 2.0), and other relevant IEC and Indian (BIS) standards.
Technical Features
State of the art DSP based system.
Stabilized and balanced outputs
Three-phase, 415V, 50Hz for air compressor.
110V DC (Boost voltage 150V DC and Float voltage 126 V DC) for battery charging and auxiliary loads.
Balanced three-phase output eliminates the need of special auxiliary motors there by reducing the cost of auxiliary motors.
Wide DC Input variation (500 - 990 VDC) including 4.5% ripple and safety margin.
Maintenance free, being fully static.
Low noise level.
Underslung structure with IP65 protection class.
Online monitoring.
Event and Data logging facility.
Natural cooled.
Boost and Float changer for smooth charging of battery.
Applications
Converts third rail DC input voltage with wide variation to stabilized three-phase, 415V, 50 Hz voltages for air compressors and 110V DC for battery charging and auxiliary loads.
Technical Specifications
A. Input
Factors
Values
Nominal Voltage
750 V DC Range 500 – 990 VDC including 4.5% ripple
B. Output
Factors
Values
Output power
25 kVA, Three- phase, 415 V, 50 Hz AC and 25 kW, 110 V DC
Output AC current ripple
for 25kVA AC, < 5% at full load upto 20th harmonics upto 1000Hz
Output AC current waveform
Close to sinusoidal (for 25 kVA AC)
Efficiency
>92%
C. General
Factors
Values
Operating ambient temperature
5°C to 55°C
Cooling
Natural
Display & Communication part
Vacuum fluorescent display (VFD and RS232, CAN part for data retrieval)