Products : Transportation Sector (Rail Road Application) : Power Switchgear : Tap Changer:Tap Changer
Tap Changer
      Product Details
      Salient Features
      Applications
      Technical Specifications
       
      Product Details
     
Autometers Alliance Ltd is manufacturing "On Load Single Phase High Voltage Tap Changer Type NO 32" for electric locomotive in accordance with IEC 60077-1 (1999-10). The project is undertaken in technical collaboration with Ganz Transelektro Traction Electrics Ltd, Hungary.
       
      Salient Features
     
  • No break of transformer current during changing of tap voltages.
  • A total of 32 taps provided for smooth changeover of voltages.
  • Air insulated circuit breaker with magnetic blow out coil is mechanically coupled with taps of selector for switching in and out of the transition resistor during current transition phase.
  • Four cylinder electro-pneumatic air motor to actuate the tap changer at high switching speed in both up and down directions.
  • Independent serviceability of loco transformer oil and tap changer oil.
  • Manual drive arrangement in case of failure of electrical control of OLTC.

Applications

On Load Single Phase High Voltage Tap Changer Type NO 32 is used on high voltage side of AC electric locomotive transformer to control the voltage of traction motor in both the directions.

Main Subsystems

  • Selector
  • Circuit breaker
  • Air motor

Accessories supporting the subsystems

  • Manual hand drive
  • ZSM panel
  • Selsyn receiver
  • Transition resistance
       
      Technical Specifications
     

Factors

Values

Rated voltage

25 kV

Maximum service voltage

27.5 kV

Operating voltage range

17.5 kV - 27.5 kV

Rated current

400 Amp

Rated frequency

50 Hz

Maximum tapping voltage

2000 V

Transition resistance

1.61 Ω ± 10%

Operating pressure of air motor

2.5 – 3.5 kP/cm2

Rated voltage of the control valve

110 VDC

No. of  taps

32

Short Circuit Current Rating

Contact roller of the tap selector

10 kA peak

Contact of the circuit breaker