Products : Transportation Sector (Rail Road Application) : Power Conditioning : Electric Locomotives:IGBT Based 180 kVA, 750V/830 1ø, 50Hz to 415V, 3ø, 50Hz (DC Propulsion)
IGBT Based 180 kVA, 750V/830 1ø, 50Hz to 415V, 3ø, 50Hz (DC Propulsion)
      Product Details
      Salient Features
      Applications
      Technical Specifications
       
      Product Details
     
Autometers Alliance Ltd offers 180 kVA IGBT based Static Converter. The product is designed to meet requirements of IEC 60571 (Edition 2.1), IEC 61287-1 (Edition 2.0), IEC 60310 (Edition 3.0), IEC 61373 (Edition 2.0) and other relevant IEC and Indian ( BIS) Standards.
       
      Salient Features
     
  • State of the art DSP based system
  • Stabilised and balanced output at 415 V and 50 Hz with minium distortion
  • Eliminates the need of special auxiliary motors thereby reducing the cost of auxiliary motors
  • Near unity power factor achieved using 4 quadrant front end converter
  • Maintenance free, as supply is static
  • Less noise
  • Event and data logging facility helps in diagnostics
  • Electrically and functionally one to one replacement of Arno Converter
  • Online monitoring
  • Controlled battery charger with galvanic isolation between converter and battery
  • Eliminates the disadvantages of rotary converter
  • Optical link between DSP and power devices

Applications 

Converts single phase input voltage with typical railway characteristics to stabilised 3-phase voltages for the safe and reliable operation of electrical equipment onboard railway vehicles.

       
      Technical Specifications
     

Factors

Values

Nominal voltage

AC single phase, 380 V or 415 V, -22%, +33% (corresponding to catenary voltage of 22.5 kV)

Powar factor Close to unity

Frequency

50±8% Hz

Regeneration facility Available due to front end 4 quardrant operation

Factors

Values

Output Power

180 kVA, 0.8pf (at nominal operation)

Overload 200% for 5 sec (360 kVA & current limit of 600A)

Voltage 1

AC 415 ± 5%, 3-phase system

Voltage 2

DC 110V ±5% ripple (rms) at full load

Waveform

Sine wave

Total harmonic distortion in voltage

<=10% (up to 20th harmonic)

Efficiency

>=92% (at nominal input voltage)

Factors

Values

Operating ambient temperature 

0 to 70 °C

Cooling

Forced air cooling

Display & communication port

Vacuum fluorescent display (VFD) and RS-232 port for online monitoring and data retrieval

Control voltage 

Nominal (77 to 137.5 V)

Mounting

Onboard floor mounting

Weight ~1400kg

Envelope size

670x1765x1700 mm (approx)